For years, whenever a client asked me “what level of detail do you need for the model?”, I felt a small pang of guilt, because I knew that my honest answer was “it depends”, and that this answer was not what they wanted to hear. They wanted a number. LOD 200, LOD 300, LOD 350. A number fits in a contract. A number is easy to write on a slide. But every time I gave one, I knew that it left out the real questions: needed for what? By whom? At which moment? And what about the data, not only the shape?
ISO 7817-1 is the international standard that finally gives those questions a framework. Published in June 2024, it is the standard behind the term Level of Information Need (LOIN), and it gives a consistent method for specifying what information is needed, for which purpose, at which milestone, for which actors and for which objects. It replaced, in Europe, the earlier European standard EN 17412-1, whose content it carries forward as EN ISO 7817-1.
I have written LOD matrices for many projects, and I have watched the industry slowly shift its vocabulary. This guide explains the standard in practical terms: what it contains, how its framework works, what its three types of information mean, how to write specifications that can be checked, and how to move from LOD thinking to LOIN thinking without losing your team on the way.
The Short Answer
ISO 7817-1 is titled Building information modelling: Level of information need, Part 1: Concepts and principles. Its published scope says that it:
- specifies concepts and principles to establish a methodology for specifying level of information need and information deliveries in a consistent way when using BIM;
- gives guidelines for the principles required to specify information needs;
- can be applied to general information exchange, to a collaborative work process and to an appointment with specified information delivery;
- applies to the whole life cycle of any built asset, from strategic planning to end of life.
In practical words:
LOIN is not a scale from 100 to 500. It is a way of describing, in a structured and verifiable way, the minimum information needed, so that nobody produces more or less than what is required.
It was published on 20 June 2024, with the European adoption following shortly after. If you have read about EN 17412-1, you already know most of the ideas. The ISO text consolidates them internationally.
For the comparison with the older approaches, see Level of Information Need vs. LOD vs. LOI: Key Differences and BIM Levels of Development (LOD) Explained.
Why a Standard for Information Need?
The standard exists because projects were wasting effort in both directions.
| Problem | Typical cause |
|---|---|
| Over-delivery: heavy models, endless detail nobody uses | “LOD 400 for everything”, requirements copied from another project |
| Under-delivery: missing data at the moment someone needs it | Requirements that describe geometry but not properties or documents |
| Disputes: arguments about whether a deliverable meets the contract | Requirements that cannot be checked |
| Mismatch: two parties using the same term for different things | No shared definition of what “level” means |
ISO 7817-1 addresses all four by asking for a structured specification of need, with a defined vocabulary, that can be agreed in advance and verified afterward. The guiding principle, also expressed in ISO 19650, is to provide what is needed and no more. See ISO 19650-1: Information Management Concepts and Principles.
The Structure of the Standard
Based on the standard’s published table of contents, the main body is organized as follows.
| Clause | Content |
|---|---|
| General | Principles and context |
| Framework to specify the level of information need | The four considerations: purposes, milestones, actors and objects |
| Definition of level of information need and its subdivision | Geometrical information, alphanumerical information, documentation and their relationships |
| Verification and validation | How to check that information meets the need |
| Annexes (informative) | An overview of main concepts relating to information exchange, and examples of methods to specify level of information need |
If you remember this structure, you can navigate the whole standard: a framework (who, what, when, why), a subdivision (what kinds of information), and a way to check (verification and validation).
The Framework: Four Things to Consider
The standard asks you to consider four elements when specifying the level of information need. I call them the four questions.

1. Why? Consider the Purposes
Every information need exists because of a purpose: a decision to be made, an analysis to run, a task to perform. Examples: design coordination, cost estimation, fire safety review, energy simulation, facility maintenance.
The purpose determines which information matters. A purpose of “quantity takeoff” needs accurate dimensions and classification. A purpose of “maintenance planning” needs asset identification, location and maintenance data. If you cannot state the purpose, you cannot justify the requirement.
2. When? Consider the Information Delivery Milestones
Information needs change over time. At concept stage, a wall needs little; at construction stage, it needs more. The standard asks you to tie each requirement to an information delivery milestone: a defined point at which information is delivered and reviewed.
These milestones appear in the MIDP, the BEP and the EIR. See Master Information Delivery Plan (MIDP): Complete Guide.
3. Who? Consider the Actors
Information is provided by someone and used by someone. The standard asks you to identify the actors involved, with their roles in the exchange: for example, the architect who provides, the structural engineer who receives, the cost consultant who uses.
Naming the actors prevents the classic misunderstanding in which the provider produces what is easy and the user needs something different.
4. What? Consider the Objects Within a Breakdown Structure
Finally, you specify the information for objects: walls, doors, pumps, spaces, systems. Since you cannot specify each element in a building individually, the standard asks you to organize objects within a breakdown structure, for example by a classification system or a system hierarchy, and to specify needs for groups.
A classification system is the natural tool here. See BIM Classification Systems Compared: Uniclass, OmniClass, Uniformat, and MasterFormat.
The Three Kinds of Information
Once the framework is in place, the standard divides the level of information need into three kinds of information.

Geometrical Information
This is the information about shape and position. The standard subdivides it into five aspects.

| Aspect | What it specifies | Practical example |
|---|---|---|
| Detail | How closely the shape represents the object | A simplified box for a pump versus a model with connections and flanges |
| Dimensionality | Whether the object is represented as a point, line, surface or solid | A tree as a point symbol, a cable route as a line, a wall as a solid |
| Location | Where the object is, absolute or relative, and with what accuracy | Position relative to a grid, or in project coordinates |
| Appearance | How the object looks: color, texture, symbol | Material appearance for visualization, or a standard symbol for drawings |
| Parametric behavior | How the object reacts to parameters and rules | A door that adapts to the wall thickness |
The standard also addresses the relationships and prerequisites between these aspects. For example, a precise location requires a sufficiently defined geometry to measure from.
Why separate them? Because real needs differ. A cost estimator may need accurate dimensions but no appearance. A visualization may need appearance but low accuracy. A coordination check may need accurate location and solid dimensionality but no parametric behavior. Specifying them separately avoids requesting the most demanding value for everything.
Alphanumerical Information
This is the non-graphical data. The standard subdivides it into two parts.
- Identification: how the object is identified: a unique identifier, a name, a type reference, a classification code.
- Information content: the properties and values: fire rating, material, manufacturer, capacity, cost code.
The distinction is useful. Identification lets you find and link objects across models, documents and systems. Content tells you what they are like. Many failed handovers have good content but poor identification: the data exists but cannot be tied to anything.
For properties, shared definitions help enormously: see buildingSMART Data Dictionary (bSDD) Explained and ISO 23387: BIM Data Templates Explained.
Documentation
This is information in document form: reports, drawings, specifications, certificates, manuals, photographs. The standard treats documentation as a kind of information need in its own right, with the same logic of purpose, milestone, actors and objects: which documents, for which objects, delivered when, to whom.
Documentation is where many requirements stay vague. “Provide O&M manuals” is not a requirement. “Provide, for each item of plant in the asset register, a manufacturer’s maintenance manual in PDF, linked to the asset identifier, at handover” is.
Verification and Validation
The standard includes a clause on verification and validation, which signals something important: a specification of need is incomplete unless it says how it will be checked.
In quality management, the two words have different shades of meaning.
- Verification asks: does the information meet the specified requirements? (Are the required properties present? Is the geometry at the specified detail?)
- Validation asks: is the information fit for its intended purpose? (Can the cost estimator actually produce an estimate from it? Can the maintenance team use it?)
Both matter. A model can be verified against every item of the specification and still fail validation if the specification itself missed what the purpose required.
Practical Ways to Check
- Rule-based model checking for properties, naming, classification and geometric rules. See BIM Model Checking: Geometric and Information Validation.
- Machine-readable specifications such as IDS for alphanumerical requirements on IFC models. See Information Delivery Specification (IDS): The Complete Guide.
- Visual review for geometry, appearance and consistency.
- Document checks for completeness and linkage.
- Purpose tests: try to perform the task the information was meant for, on a sample, before the full delivery.
Planning verification at the time of writing the requirement leads to a healthy discipline: if you cannot see how a requirement would be checked, rewrite it.
Methods to Specify Level of Information Need
The standard does not impose a single format. Its informative annex gives examples of methods to specify LOIN. In practice, teams use a few recurring approaches.
1. The Specification Matrix
A table with objects (grouped by classification) in rows and milestones in columns, with the required information for each cell. This is the descendant of the LOD matrix and the Model Element Table.
| Object group | Purpose | Milestone | Geometry | Alphanumerical | Documentation |
|---|---|---|---|---|---|
| Structural beams | Coordination | Design development | 3D solid, accurate section and location | ID, classification, material, fire protection requirement | None |
| External doors | Fire safety review | Technical design | 3D solid with swing, positioned in host | ID, classification, fire rating, acoustic rating, hardware set | Test evidence reference |
| Air handling units | Maintenance | Handover | Simplified volume with connection points | ID, location, manufacturer, model, serial number, maintenance interval | Manufacturer O&M manual |
2. The Per-Purpose Specification
A description of the needs for each purpose separately (for example, “all information needed for cost estimation at milestone 2”), then combined into an overall specification. This works well when purposes are few and clear.
3. Structured Digital Specifications
Specifications written in a machine-readable form, such as IDS for alphanumerical requirements, or schema-based approaches that describe geometry, data and documentation together. These allow automated checking and reduce ambiguity. The community is actively developing such approaches, so check current work and tools before choosing.
4. Data Templates
Using data templates from a standard data dictionary to define the properties for each object type, so the same definition is reused in every project. See ISO 23387: BIM Data Templates Explained.
A Worked Example: From a Vague Requirement to a LOIN Specification
Let me show the transformation I do in workshops. Start with a typical requirement.
“Mechanical equipment shall be modeled at LOD 350.”
Step 1: Ask why. The client says it is for clash detection and for handover to the facility team. Those are two purposes, so we need two sets of requirements.
Step 2: Ask when. Clash detection is needed at the end of technical design. Handover data is needed at practical completion.
Step 3: Ask who. For clash detection, the MEP engineer provides and the BIM coordinator checks. For handover, the contractor provides and the facility manager uses.
Step 4: Define the objects. “Mechanical equipment” is split by classification: air handling units, fans, pumps, boilers.
Step 5: Specify the three kinds of information per purpose.
| Purpose A: Coordination | Purpose B: Maintenance | |
|---|---|---|
| Milestone | End of technical design | Practical completion |
| Geometry | Solid volume with accurate position, clearances and connection points | Location only (room reference), no detailed geometry required |
| Identification | Unique identifier, classification code | Unique identifier matching the asset register, classification code |
| Information content | System reference, capacity (for clearance rules) | Manufacturer, model, serial number, installation date, maintenance interval, warranty end date |
| Documentation | None | Manufacturer O&M manual, commissioning certificate |
| Verification | Clash detection and clearance check | Data completeness check against the asset register, document linkage check |
Step 6: Record it in the EIR and respond in the BEP.
Look at what changed. The original sentence spoke only of geometry and implied the same level for every purpose. The LOIN version shows that the maintenance purpose does not need detailed geometry at all, while the coordination purpose does not need serial numbers. Each party now knows exactly what to produce, and a checker knows exactly what to verify.
LOIN and LOD: How to Live With Both
Many teams ask: “Can we convert LOD 300 into LOIN?” The honest answer is that there is no direct conversion, because LOD bundles geometry and information into one number, while LOIN separates them and adds purpose, milestone and actors. But you can bridge the two practically.
A Pragmatic Bridge
- Keep LOD as shorthand for geometry where your clients and partners use it. For example: “geometry at LOD 300 per the agreed specification”.
- Specify alphanumerical information and documentation separately, using LOIN logic.
- Add purpose and milestone to every row of your matrix.
- Name your reference documents and editions: “LOD per BIMForum Specification, edition X” and “information need per ISO 7817-1”.
- Be explicit when a contract uses both, to avoid contradictions.
What Not to Do
- Do not claim “LOIN compliant” because you added a few properties to a LOD table. LOIN means the framework is applied: purposes, milestones, actors and objects.
- Do not translate LOD numbers into LOIN levels mechanically. There is no official mapping.
- Do not abandon LOD vocabulary overnight with partners who rely on it. Bridge gradually.
See BIM Levels of Development (LOD) Explained.
Where LOIN Appears in the ISO 19650 Process
LOIN is not a standalone exercise. It plugs into the information management process.
| Document or activity | Role of LOIN |
|---|---|
| PIR / AIR | Express needs in terms of purposes and information, from which LOIN specifications are derived |
| EIR | Contains the LOIN specification for each appointment, per milestone |
| BEP | The delivery team’s response, showing how it will produce the specified information |
| MIDP / TIDP | Schedule when the specified information is delivered and by whom |
| Responsibility matrix | Shows who produces which information |
| Quality checks and acceptance | Verify and validate against the LOIN specification |
See Exchange Information Requirements (EIR): Complete Guide, BIM Execution Plan (BEP): How to Create and Implement One and ISO 19650-4: Information Exchange Requirements Explained.
Relationship With IFC, IDS and Data Dictionaries
LOIN is a method, not a file format. To use it in software workflows, it connects with other standards.
- IFC (ISO 16739-1) is the schema in which geometry, identification and properties can be exchanged. See ISO 16739 and the IFC Standard Explained.
- IDS expresses alphanumerical requirements for IFC models in a machine-readable form, enabling automated checking. IDS does not cover geometry and documentation in the same way that LOIN does, so the two are complementary rather than equivalent.
- Data dictionaries and data templates (ISO 23386 and ISO 23387) provide shared definitions of properties, so that “fire rating” means the same thing everywhere. See buildingSMART Data Dictionary (bSDD) Explained.
- Classification systems provide the breakdown structure for grouping objects.
The practical picture is a chain: LOIN says what is needed, classification groups the objects, dictionaries define the properties, IDS checks the data in IFC.
Common Mistakes With LOIN
- Treating LOIN as a new scale. It is a specification method. There is no “LOIN 3”.
- Specifying everything for everything. The principle is “what is needed, no more”. Group objects and focus on purposes.
- Forgetting documentation. Many handover failures are about documents, not models.
- Forgetting identification. Properties without identifiers cannot be linked to the asset register.
- No verification plan. If it cannot be checked, it is a wish.
- Ignoring actors. Without a named user, the requirement drifts toward what is easy to produce.
- Copying a matrix from another project. Purposes, milestones and objects differ.
- Over-engineering for small projects. A half-page table can be a valid LOIN specification.
- Writing requirements that contradict the software’s capabilities. Test what your tools can produce and check.
- Mixing LOD and LOIN without saying so. Be explicit about references.
See also Common BIM Mistakes Beginners Should Avoid.
A Practical Method in Eight Steps
Here is the method I use with clients. It follows the framework of the standard.
- List the purposes for which the information will be used. See BIM Uses Explained: What Is BIM Actually Used For?.
- Define the milestones at which information is delivered.
- Identify the actors: who provides, who uses.
- Group the objects using a classification or a system breakdown.
- For each group, purpose and milestone, specify the geometrical information (aspects needed), the alphanumerical information (identification and content) and the documentation.
- Define verification and validation: how each requirement will be checked, and by whom.
- Write the specification in a form your team can maintain: a matrix, a structured file, or both. Put it in the EIR.
- Test with a sample. Ask a team to produce a small part against the specification and check it. Revise.
Frequently Asked Questions
What is ISO 7817-1?
The international standard that specifies concepts and principles for specifying the level of information need and information deliveries using BIM. It was published in June 2024.
What is the level of information need (LOIN)?
A framework that defines the extent and granularity of information needed for a given purpose, milestone, actor and object, covering geometrical information, alphanumerical information and documentation.
What replaced EN 17412-1?
EN ISO 7817-1, the European adoption of ISO 7817-1, replaced EN 17412-1.
Is LOIN the same as LOD?
No. LOD is a scale that bundles geometry and information. LOIN is a method to specify information need in a structured way, with separate treatment of geometry, data and documentation, tied to purposes, milestones and actors.
Does ISO 7817-1 define LOD 100 to 500?
No. The standard defines a framework for specification, not a numbered scale.
What are the five aspects of geometrical information?
Detail, dimensionality, location, appearance and parametric behavior.
Does the standard cover how to verify information?
Yes. It includes a clause on verification and validation, reflecting that a specification should be checkable.
Do I need to buy the standard?
If you cite it in contracts or tenders, you should read the official text, available from ISO or your national standards body. This guide is an introduction, not a substitute.
Is IDS the same as LOIN?
No. IDS is a technical standard for machine-readable requirements on IFC models, mainly alphanumerical. LOIN is a broader methodology that also covers geometry and documentation.
Can I use LOIN on a small project?
Yes. Use the four questions and produce a short table. The principle scales down easily.
Final Thoughts
I no longer feel guilty when a client asks me what level of detail they need. I ask them four questions instead: why do you need it, when, who will use it and for which objects? Most clients find that these questions are easier to answer than they expected, and that the answers are far more useful than a number.
That is the quiet success of ISO 7817-1: it takes the conversation we always should have had and gives it a shape that fits into a contract, a plan and a check. It will not write your specification for you. But it will make it very difficult to write a vague one without noticing.
Where to go next: to see the older and newer approaches side by side, read Level of Information Need vs. LOD vs. LOI: Key Differences. To write the actual requirements, continue with Exchange Information Requirements (EIR): Complete Guide, and to automate checking, Information Delivery Specification (IDS): The Complete Guide.