Model View Definitions (MVD): Understanding IFC Exchange Requirements

Model View Definitions (MVD): Understanding IFC Exchange Requirements

There is a question that I now ask at the start of every project that uses IFC, and the answers are always instructive. The question is: “When you say IFC, which part of IFC do you mean?” The usual response is a short silence. People know the version, sometimes. They know that the file ends in .ifc. But very few can say which subset of the schema they expect to receive, what is supposed to be in it and what is supposed to be left out.

This is not a trivial gap. IFC is a very large schema: it can describe thousands of kinds of things in a building, from structural analysis models and cost items to work schedules and electrical circuits. No single exchange uses all of it. A coordination exchange needs shapes, names, spatial structure and a few properties. A structural analysis exchange needs loads and boundary conditions. A handover needs asset data. If the sender and the receiver do not agree on which subset is in play, they will each interpret the same file differently, and each will be right according to their own assumptions.

The Model View Definition (MVD) is the mechanism that closes this gap. An MVD is, in effect, a contract between software: “for this kind of exchange, these parts of the schema must be written by the sender and understood by the receiver”. It is also one of the least discussed concepts among day-to-day BIM users, because it works in the background, inside the software’s export and import functions. As a CAD manager who spent a decade explaining export settings to users, I have come to think that understanding MVDs, even at a high level, makes you a better specifier and a better troubleshooter.

In this guide, I explain what an MVD is, how it relates to the IFC schema, the IDM and IDS, which MVDs you are likely to meet, how certification works, how to specify an MVD in a project and what its limits are. I checked the current picture against buildingSMART’s public documentation and vendor documentation. For the standard itself, see ISO 16739 and the IFC Standard Explained.


The Short Answer

A Model View Definition (MVD) identifies which subset of the IFC schema is used for a specific exchange, and imposes requirements on software that implements it. ISO 16739-1 describes MVDs in these terms: different implementation levels can be defined to better support multiple information deliveries, and each MVD identifies which subset of the definitions imposes requirements for implementation in software applications. Software seeking certification has to say which MVD it conforms to.

Model View Definitions: a subset of IFC for one exchange

In one sentence:

The IFC schema is the dictionary. An MVD is the list of words that this particular conversation is allowed to use.

An MVD usually comes with three ingredients:

  1. Exchange requirements: what information has to be exchanged for a defined purpose.
  2. A subset of the schema that can express those requirements.
  3. Rules for how the information must be represented, so that sender and receiver interpret it identically.

Why MVDs Exist

IFC is deliberately general. Its designers wanted one schema for all kinds of exchange across the life cycle. The price of generality is that there are many valid ways to express the same thing: a wall can be described by an extrusion, by a faceted solid or by a triangulated mesh; a property can be attached to an occurrence or to a type. A receiving program cannot be expected to understand every possible choice.

An MVD narrows the choices. It says: “for this exchange, express walls this way, attach these properties this way, and these relationships are mandatory”. That narrowing makes software implementation feasible and exchange predictable.

Related Concepts: IDM, MVD and IDS

People often confuse three layers of specification. Here is how they relate.

ConceptLevelWhat it describesWho typically uses it
IDM (Information Delivery Manual), ISO 29481ProcessThe business process and the information that must be exchanged within it, in terms a practitioner can followDomain experts defining exchange needs
MVD (Model View Definition)SchemaThe subset of IFC and the rules that implement the exchange requirementsSoftware developers, certification bodies
IDS (Information Delivery Specification)Project dataThe specific information a project requires in a given IFC file, in testable formClients, BIM managers, checkers. See Information Delivery Specification (IDS): The Complete Guide

buildingSMART describes IDS as complementary to MVD: the MVD deals with fundamental structural questions of an exchange, while IDS expresses project-specific requirements on the information in the data. A useful way to remember it: IDM says why and who, MVD says how in the schema, IDS says what in this project.


How an MVD Is Built

You do not need to write one, but understanding the ingredients helps you read documentation.

Exchange Requirements

An MVD begins with a list of exchange requirements: statements of information needed for a purpose. For example: “the receiver must be able to identify each building storey and the elements contained in it”, or “walls must carry their base geometry and a name”.

Concept Templates

The schema is described in terms of reusable concepts: ways of representing a thing, such as “an object’s geometry”, “an object’s property set” or “a space boundary”. A concept template defines such a pattern. Each IFC version has a general usage MVD with a set of concept templates, regarded as part of the standard.

Rules and Restrictions

The MVD then says, for each exchange requirement, which concepts must be used, on which entities and with which restrictions. For example: “Walls shall have an extruded or faceted geometry, shall be contained in a storey and shall have the common wall property set available”.

Machine-Readable Form

MVDs are expressed as electronically readable specifications (mvdXML), so that software can be tested against them and checkers can verify files against them. That is how certification tests are possible.


The MVDs You Are Likely to Meet

IFC 2×3: Coordination View 2.0

The Coordination View 2.0 is the most widely implemented MVD of the IFC schema. It defines the exchange of spatial structure, building elements and building service elements for coordination and reference. The vast majority of software certified for IFC 2×3 is certified for this view, for both export and import. Note that this view does not include round-trip data exchange.

Related views exist:

  • Coordination View (surface geometry): a simplified publishing subset suitable for viewing, coordination and clash checking, which all viewers can handle.
  • Basic FM Handover View: an extended version of the Coordination View that defines general requirements for design applications to support handover of facility management information.
  • Other views specified by organizations outside buildingSMART, usually as extensions of the coordination view.

IFC4: Reference View and Design Transfer View

For IFC4, buildingSMART divided the coordination view into two more specific views.

ViewPurposeNotes
Reference ViewExchange of models for reference, mainly in one directionSuitable for all workflows based on reference models; can be understood as a Coordination View 2.0 with a slightly reduced and more focused range
Design Transfer ViewExchange supporting limited editing of interconnected elements: inserting, deleting, moving and modifying physical elements and spaces, within a limited parametric scopeIntended, for example, for an architect passing building information to an engineer who may modify geometry. Not meant for round-trip exchange

In practice, Reference View is the default choice for coordination exports from IFC4-capable tools. Design Transfer View has been less widely implemented and certified, and tools differ in how well they support it.

IFC 4.3: Views Under Development and Implementation

buildingSMART’s MVD policy for IFC 4.x listed candidate views for the 4.3 generation, including a Reference View, an Alignment-Based Reference View (for infrastructure positioned along alignments), a Design Transfer View and an Asset Management handover view, and referred to draft MVDs for bridges and other infrastructure domains. The policy also states the intention to enable certification of 4.3 views soon after formal release. The status of individual views and of certification changes over time, so check buildingSMART’s current documentation. See IFC 2×3 vs. IFC4 vs. IFC4.3: Key Differences.

Other and Local Views

Some views are defined for specific purposes or markets: for example, handover data in the COBie structure, or national and regulatory views that add local requirements to an IFC base. Check the documentation of your client or authority. See COBie Explained: The Complete Guide to BIM Asset Data Handover.


Where You See the MVD in Practice

In the Export Dialog

Most authoring tools let you pick the model view or exchange requirement at export, for example “Coordination View” or “Reference View”. That selection tells the exporter which subset to write.

In the File Header

An IFC file normally states the view definition it claims to follow in its header, as a view definition entry. When you receive a file, read it. It is the fastest way to confirm that the file claims to match the specified view. See IFC Files Explained: Structure, Classes, and Properties.

In Certification

buildingSMART operates a software certification program in which software is tested for export and import against defined MVDs. Historically, the most widely adopted certification has been for the IFC 2×3 Coordination View 2.0, and IFC4 certification has been split between the Reference View and Design Transfer View. buildingSMART has been developing a new, multi-tier approach to certification and validation of IFC data and software, so the details evolve. Note that the existing certified views do not cover data round trips.

In Requirements

Clients write MVDs into their EIR: “IFC4, Reference View”. It is a short phrase with significant consequences.


What Certification Does and Does Not Tell You

Certification is a helpful signal, but it is easy to misread.

What it tells youWhat it does not tell you
The software passed buildingSMART’s tests for a specific MVD and direction (export or import) at a given versionThat every export from the software will be correct for your project
The implementation handles the required concepts for that viewThat your content requirements (properties, classification, quantities) are met
The vendor has engaged with the standardThat other views or other schema versions are supported equally well
A reasonable baseline of interoperabilityThat round-trip editing will work

Practical advice:

  • Check the current certification list for the software, version, view and direction (export or import) that matter to you.
  • Remember that import and export are certified separately, and that some tools are certified for export of a view but not for import.
  • Use certification to shortlist, and pilot tests to decide.

How to Choose and Specify an MVD

Step 1: Identify the Purpose of the Exchange

PurposeTypical choice
General coordination and clash detectionCoordination View 2.0 (IFC 2×3) or Reference View (IFC4)
Reference model for design in another toolReference View
Limited editing of interconnected elements by another disciplineDesign Transfer View, if supported and tested
Facility management handoverA handover view or structured asset data, with defined properties
Infrastructure exchange along alignmentsAlignment-based view in IFC 4.3, where supported
Regulatory submissionThe authority’s specified view and any local requirements

Step 2: Check What Your Tools Support

List each party’s software, version and certified views for export and import. Do not assume that a view is supported by every tool in the chain.

Step 3: Pilot

Export a sample in the chosen view and import it where it will be used. Check geometry, classes, properties and structure.

Step 4: Write the Specification Precisely

State in the EIR and BEP:

  • the IFC schema version (for example IFC4);
  • the MVD (for example Reference View);
  • the content requirements beyond the MVD, using the level of information need and IDS;
  • the validation method;
  • the responsibilities for exporting and checking.

An example of a complete statement: “Models shall be exchanged as IFC4 in the Reference View, with the property sets and classification specified in the attached IDS, validated before sharing.”

Step 5: Do Not Expect the MVD to Say Everything

The MVD defines how information is structured in the schema, not what your project needs in it. Two files can both conform to the same MVD and still differ greatly in content: one with all your required properties, the other with none. That is why MVD and IDS are used together.


MVD, LOIN and IDS: Dividing the Work

It helps to give each tool its job.

QuestionAnswer from
Which part of the IFC schema is used for this exchange?MVD
Which information (geometry, data, documents) is needed for which purpose, milestone and actors?LOIN (ISO 7817-1)
How is the data requirement expressed in a testable way for IFC?IDS
What do the properties mean?bSDD and data templates
Is the file valid IFC?Validation

See ISO 7817-1: Level of Information Need Explained, buildingSMART Data Dictionary (bSDD) Explained and How to Validate IFC Models for Data Quality and Compliance.


Limits and Practical Cautions

  1. An MVD is not a guarantee of quality. It defines structure, not completeness or correctness of your data.
  2. Support varies. Tools implement views to different depths. A tool can export “Reference View” with settings that omit things your project needs.
  3. Views and schema versions go together. A view belongs to a schema version. Do not mix them.
  4. Certification changes. The program is being redeveloped. Check current information.
  5. Round trips are not covered. The common certified views are not designed for round-trip editing.
  6. Custom extensions break assumptions. Extensions of an MVD for local needs can be valuable, but the receiver must know about them.
  7. The documentation is technical. The formal MVD documentation is written for implementers. For users, vendor help pages and buildingSMART guidance are more accessible.

Common Mistakes

  1. Writing “IFC” with no version or view.
  2. Choosing a view that your tools cannot actually write or read well.
  3. Assuming a certified tool will always produce a perfect file.
  4. Using Design Transfer View as if it supported round trips.
  5. Never reading the file header to check which view the file claims.
  6. Expecting the MVD to guarantee the presence of required properties.
  7. Mixing views within one coordination without checking.
  8. Ignoring import-side certification.
  9. Not retesting after software updates.
  10. Treating MVD and IDS as alternatives instead of complementary tools.

See also Common BIM Mistakes Beginners Should Avoid and BIM Interoperability Problems and How to Solve Them.


A Short Checklist

  1. Have we identified the purpose of each exchange?
  2. Have we chosen the schema version and view for each purpose?
  3. Do all parties’ tools support it for the needed direction (export or import)?
  4. Have we checked certification status and run a pilot?
  5. Are the version and view written in the EIR and BEP?
  6. Are content requirements specified separately, with LOIN and IDS?
  7. Do we check the header of received files?
  8. Do we validate files and check requirements?
  9. Do we retest after software updates?
  10. Do we know who is responsible for exports and checks?

Frequently Asked Questions

What is an MVD in BIM?

A Model View Definition: the specification of a subset of the IFC schema used for a particular exchange, with rules for how information is represented, so that software can implement and be tested against it.

What is the difference between IFC and an MVD?

IFC is the full schema. An MVD selects and constrains the part of IFC used for one exchange.

What is the Coordination View 2.0?

The most widely implemented MVD of IFC 2×3, used for design coordination and general exchange of building models.

What are the IFC4 Reference View and Design Transfer View?

Two views of IFC4. The Reference View supports mainly one-directional exchange of reference models. The Design Transfer View supports limited editing of interconnected elements but is not meant for round trips.

Is an MVD the same as an IDS?

No. An MVD defines the schema subset and its rules. An IDS specifies the information a project requires in the data. They complement each other.

What is an IDM?

An Information Delivery Manual (ISO 29481) describes a business process and the information exchanged in it. An MVD can implement the exchange requirements of an IDM in the IFC schema.

Where do I see which MVD a file uses?

In the header of the IFC file, in the view definition entry, and in the export settings of the software that produced it.

Does certification guarantee a perfect export?

No. It shows that the software passed tests for a specific view and direction. You still need to test your own exports.

Which MVD should I use for coordination?

Typically Coordination View 2.0 for IFC 2×3 or Reference View for IFC4, depending on what your tools support well. Pilot it.

Which MVD applies to IFC 4.3?

Views are under development and implementation, including reference and alignment-based views. Check current buildingSMART documentation and your software’s support.


Final Thoughts

I used to think of the “view” in an export dialog as one of those settings that you leave alone, like the paper size in a plot dialog. Years of watching exchanges succeed and fail changed my mind. The view is the promise that the sender makes to the receiver about what the file contains and how it is organized. When the promise is explicit, tested and shared, exchanges become routine. When it is left to defaults, every exchange is a small act of faith.

You do not have to become an expert in the formal documentation. You only need three habits: name the view in your requirements, check it in the file header and test it with the receiver. They take minutes, and they turn an invisible mechanism into a deliberate one.

Where to go next: to see how requirements are made testable, read Information Delivery Specification (IDS): The Complete Guide. To produce files that honor the view, continue with How to Export and Import IFC Models Correctly, and to check them, How to Validate IFC Models for Data Quality and Compliance.

Rachid Khouri

Rachid Khouri

Rachid Khouri is a CAD, BIM and GIS professional, Autodesk Authorized Developer, trainer and technical author with more than 30 years of experience, working with AutoCAD since 1992. He founded TheBIMAuthority.com to share practical guidance on BIM workflows, information management, industry standards, digital construction technologies and best practices for AEC professionals.